Home
Scholarly Works
Real-Time Detection of Interturn Faults in PM...
Journal article

Real-Time Detection of Interturn Faults in PM Drives using Back-EMF Estimation and Residual Analysis

Abstract

Interturn stator winding fault is one of the most frequent faults in permanent-magnet synchronous machines (PMSMs). In this paper, we present a new technique for online detection of this fault in PMSMs. It is based on a residual analysis improved by taking into account back-electromotive force waveform estimation, inverter model, and unbalanced inductance matrix. Then, a current residual monitoring block permits to detect the fault and its severity. The simulation and experimental results validate the proposed method and its efficiency.

Authors

Leboeuf N; Boileau T; Nahid-Mobarakeh B; Clerc G; Meibody-Tabar F

Journal

IEEE Transactions on Industry Applications, Vol. 47, No. 6, pp. 2402–2412

Publisher

Institute of Electrical and Electronics Engineers (IEEE)

Publication Date

January 1, 2011

DOI

10.1109/tia.2011.2168929

ISSN

0093-9994

Contact the Experts team