Home
Scholarly Works
Detection of body postures and movements in...
Journal article

Detection of body postures and movements in ambulatory adults with cerebral palsy: a novel and valid measure of physical behaviour

Abstract

BackgroundAccurate measurement of physical behaviour is paramount to better understand lifestyle, health, and functioning, particularly in adults with physical disability as they may be at higher risk of sedentary lifestyle and subsequent negative health consequences. This study aimed: 1) to evaluate the criterion validity of a novel and clinically applicable activity monitor (AM, Activ8), in the detection of body postures and movements in adults with spastic cerebral palsy (CP); and 2) to evaluate the extent that the AM’s positioning affects validity.MethodsIn this cross-sectional study, 14 ambulatory adults with CP [9 men; mean (SD) age, 35.4 (13.1) years] performed standardized activities while wearing three Activ8 monitors - frontolateral thigh (primary position), frontal thigh, and pant pocket - and being video recorded (criterion measure). AM activity output was compared to synchronized video recordings. Absolute (seconds) and relative [(video time–AM time)/mean time, %] time differences between methods were calculated. Relative time differences of < 10% were indicative of good validity. Comparison of AM attachment positions was completed using Spearman Rho correlation coefficients and Meng’s tests.ResultsCriterion validity of the AM (frontolateral thigh) was good (average relative time differences: 0.25% for sitting, 4.69% for standing, 2.46% for walking, 1.96% for upright activity, 3.19% for cycling), except for running (34.6%). Spearman Rho correlation coefficients were greater between video/frontolateral thigh position than video/frontal thigh position and video/pant pocket position for body posture and movement categories sitting, standing, walking, and upright activity (p < 0.01 for all).ConclusionsThe AM, positioned on the frontolateral thigh, demonstrated good criterion validity in ambulatory adults with CP. Though the Activ8 offers potential as an objective measure of physical activity, appropriate positioning is paramount for valid measurement.

Authors

Claridge EA; van den Berg-Emons RJG; Horemans HLD; van der Slot WMA; van der Stam N; Tang A; Timmons BW; Gorter JW; Bussmann JBJ

Journal

Journal of NeuroEngineering and Rehabilitation, Vol. 16, No. 1,

Publisher

Springer Nature

Publication Date

October 29, 2019

DOI

10.1186/s12984-019-0594-9

ISSN

1743-0003

Contact the Experts team