Journal article
Sulphidation resistance of composite boiler tube materials
Abstract
A lab-based testing program was undertaken to generate data to better define the sulphidation resistance of composite tubes installed in the lower-furnace section of black liquor recovery boilers. All composite tube cladding alloys tested were observed to have an acceptable corrosion rate at normal operating temperatures (up to 400°C) in the synthetic lower-furnace gaseous environment tested (1% H2S–99% N2). This acceptable corrosion resistance …
Authors
Kish JR; Eng P; Singbeil DL; Keiser JR
Journal
Materials at High Temperatures, Vol. 25, No. 2, pp. 67–79
Publisher
Taylor & Francis
Publication Date
6 2008
DOI
10.3184/096034008x330798
ISSN
0960-3409