Partial Admission Effects on the Stability of a Heat Exchanger Tube Array Academic Article uri icon

  •  
  • Overview
  •  
  • Research
  •  
  • Identity
  •  
  • Additional Document Info
  •  
  • View All
  •  

abstract

  • An experimental study is reported of the effects of partial admission on the fluid elastic stability of a heat exchanger tube array. The array geometry was a parallel triangular configuration with a pitch ratio of 1.47. Tests were conducted in a wind tunnel with uniform flow over from 33 to 100 percent of single span tubes. In these experiments, the flow location was also varied from center-span to the end supports. Additionally, tests were conducted with uniform flow over one span of two and three-span tube arrays. These results are compared with theoretical predictions.

publication date

  • May 1, 1988