Thermal neutron response of the Li2B4O7:Cu TL dosimeter

Abstract

A measurement of the thermal neutron response of the Li2B4O7:Cu TLD has been conducted. The results obtained using the Panasonic UD-806 dosimeter and UD-854A holder yield a free-in-air response of 3.3±0.1 R 60Co equivalent per mSv of thermal neutrons. A thermal neutron response of over 7 R 60Co equivalent per mSv was observed when the dosimeter was irradiated on water phantoms. The high sensitivity may result in a substantial overestimate of …