Performance of the European Society of Cardiology 0/1-Hour, 0/2-Hour, and 0/3-Hour Algorithms for Rapid Triage of Acute Myocardial Infarction Journal Articles uri icon

  •  
  • Overview
  •  
  • Research
  •  
  • Identity
  •  
  • Additional Document Info
  •  
  • View All
  •  

abstract

  • BACKGROUND: The 2020 European Society of Cardiology (ESC) guidelines recommend using the 0/1-hour and 0/2-hour algorithms over the 0/3-hour algorithm as the first and second choices of high-sensitivity cardiac troponin (hs-cTn)-based strategies for triage of patients with suspected acute myocardial infarction (AMI). PURPOSE: To evaluate the diagnostic accuracies of the ESC 0/1-hour, 0/2-hour, and 0/3-hour algorithms. DATA SOURCES: PubMed, Embase, Cochrane Central Register of Controlled Trials, Web of Science, and Scopus from 1 January 2011 to 31 December 2020. (PROSPERO: CRD42020216479). STUDY SELECTION: Prospective studies that evaluated the ESC 0/1-hour, 0/2-hour, or 0/3-hour algorithms in adult patients presenting with suspected AMI. DATA EXTRACTION: The primary outcome was index AMI. Twenty unique cohorts were identified. Primary data were obtained from investigators of 16 cohorts and aggregate data were extracted from 4 cohorts. Two independent authors assessed each study for methodological quality. DATA SYNTHESIS: A total of 32 studies (20 cohorts) with 30 066 patients were analyzed. The 0/1-hour algorithm had a pooled sensitivity of 99.1% (95% CI, 98.5% to 99.5%) and negative predictive value (NPV) of 99.8% (CI, 99.6% to 99.9%) for ruling out AMI. The 0/2-hour algorithm had a pooled sensitivity of 98.6% (CI, 97.2% to 99.3%) and NPV of 99.6% (CI, 99.4% to 99.8%). The 0/3-hour algorithm had a pooled sensitivity of 93.7% (CI, 87.4% to 97.0%) and NPV of 98.7% (CI, 97.7% to 99.3%). Sensitivity of the 0/3-hour algorithm was attenuated in studies that did not use clinical criteria (GRACE score <140 and pain-free) compared with studies that used clinical criteria (90.2% [CI, 82.9 to 94.6] vs. 98.4% [CI, 88.6 to 99.8]). All 3 algorithms had similar specificities and positive predictive values for ruling in AMI, but heterogeneity across studies was substantial. Diagnostic performance was similar across the hs-cTnT (Elecsys; Roche), hs-cTnI (Architect; Abbott), and hs-cTnI (Centaur/Atellica; Siemens) assays. LIMITATION: Diagnostic accuracy, inclusion and exclusion criteria, and cardiac troponin sampling time varied among studies. CONCLUSION: The ESC 0/1-hour and 0/2-hour algorithms have higher sensitivities and NPVs than the 0/3-hour algorithm for index AMI. PRIMARY FUNDING SOURCE: National Taiwan University Hospital.

authors

  • Chiang, Cho-Han
  • Chiang, Cho-Hung
  • Pickering, John W
  • Stoyanov, Kiril M
  • Chew, Derek P
  • Neumann, Johannes T
  • Ojeda, Francisco
  • Sörensen, Nils A
  • Su, Ke-Ying
  • Kavsak, Peter
  • Worster, Andrew
  • Inoue, Kenji
  • Johannessen, Tonje R
  • Atar, Dan
  • Amann, Michael
  • Hochholzer, Willibald
  • Mokhtari, Arash
  • Ekelund, Ulf
  • Twerenbold, Raphael
  • Mueller, Christian
  • Bahrmann, Philipp
  • Buttinger, Nicolas
  • Dooley, Maureen
  • Ruangsomboon, Onlak
  • Nowak, Richard M
  • DeFilippi, Christopher R
  • Peacock, William F
  • Neilan, Tomas G
  • Liu, Michael A
  • Hsu, Wan-Ting
  • Lee, Gin Hoong
  • Tang, Pui-Un
  • Ma, Kevin Sheng-Kai
  • Westermann, Dirk
  • Blankenberg, Stefan
  • Giannitsis, Evangelos
  • Than, Martin P
  • Lee, Chien-Chang

publication date

  • January 2022