Home
Scholarly Works
Anode surface modification regulates biofilm...
Journal article

Anode surface modification regulates biofilm community population and the performance of micro-MFC based biochemical oxygen demand sensor

Abstract

The anode surface is known to play an important role in the microbial growth and in mediating electron transfer between electroactive bacteria and the electrodes in power generating microbial fuel cells (MFCs). However, the effect of the anode surface and its modification on MFC-based biosensor performance has not been studied previously. In this study, our results show that the surface modification influences certain aspect of the biosensor performance. Plasma treatment makes the carbon cloth electrode hydrophilic with contact angle of 82 ± 5° from that of 139 ± 3° without treatment which consequently increases the amount of biofilm and produces higher current generation. Carbon nanotube (CNT) treatment doesn’t increase the amount of biofilm but significantly changes its electroactive microorganism composition from 2.3% to 17.3% that improves current generation. Interestingly, the sensitivity of the MFC sensor was not improved by either of these treatments. These findings would be important for the optimized design and manufacturing of biosensing MFCs.

Authors

Xiao N; Wu R; Huang JJ; Selvaganapathy PR

Journal

Chemical Engineering Science, Vol. 221, ,

Publisher

Elsevier

Publication Date

August 10, 2020

DOI

10.1016/j.ces.2020.115691

ISSN

0009-2509

Labels