The characteristics of the CANDU reactor relevant to severe accidents are set first by the inherent properties of the design, and second by the Canadian safety/licensing approach. Probabilistic safety assessment studies have been performed on operating CANDU plants, and on the 4 multiplied by 880 MW(e) Darlington station now under construction; furthermore a scoping risk assessment has been done for a CANDU 600 plant. They indicate that the summed severe core damage frequency is of the order of 5 multiplied by 10** minus **6/year.
Authors
Snell VG; Alikhan S; Frescura GM; Howieson JQ; King F; Rogers JT; Tamm H
Journal
Atomic Energy of Canada Limited, AECL (Report), , ,