Home
Scholarly Works
BACKUP AND ULTIMATE HEAT SINKS IN CANDU REACTORS...
Journal article

BACKUP AND ULTIMATE HEAT SINKS IN CANDU REACTORS FOR PROLONGED SBO ACCIDENTS

Abstract

In a pressurized heavy water reactor, following loss of the primary coolant, severe core damage would begin with the depletion of the liquid moderator, exposing the top row of internally-voided fuel channels to steam cooling conditions on the inside and outside. The uncovered fuel channels would heat up, deform and disassemble into core debris. Large inventories of water passively reduce the rate of progression of the accident, prolonging the time for complete loss of engineered heat sinks.The efficacy of available backup and ultimate heat sinks, available in a CANDU 6 reactor, in mitigating the consequences of a prolonged station blackout scenario was analysed using the MAAP4-CANDU code. The analysis indicated that the steam generator secondary side water inventory is the most effective heat sink during the accident. Additional heat sinks such as the primary coolant, moderator, calandria vault water and end shield water are also able to remove decay heat; however, a gradually increasing mismatch between heat generation and heat removal occurs over the course of the postulated event. This mismatch is equivalent to an additional water inventory estimated to be 350,000 kg at the time of calandria vessel failure. In the Enhanced CANDU 6 reactor ∼2,040,000 kg of water in the reserve water tank is available for prolonged emergencies requiring heat sinks.

Authors

NITHEANANDAN T; BROWN MJ

Journal

Nuclear Engineering and Technology, Vol. 45, No. 5, pp. 589–596

Publisher

Elsevier

Publication Date

January 1, 2013

DOI

10.5516/net.03.2013.711

ISSN

1738-5733

Contact the Experts team