Heat transfer to a moving packed bed of nickel pellets Journal Articles uri icon

  •  
  • Overview
  •  
  • Research
  •  
  • Identity
  •  
  • Additional Document Info
  •  
  • View All
  •  

abstract

  • AbstractHeat transfer between a bed of nickel pellets and a vertical section of electrically heated steel pipe has been measured, with the pellet bed inside the vertical pipe. Most of the data are for a 20.27 cm diameter pipe but some data were also obtained for a 10.23 cm diameter pipe. The effective thermal conductivity of the stationary pellet bed has been estimated approximately from the results of unsteady heating tests. Tests have been carried out with a downwardly moving bed, including the effect of air flowing upwards through the bed. Average values of the pellet‐side heat transfer coefficient are between 72 and 135 W/(m2°C) depending on the mass fluxes of air and pellets, and have been expressed as an empirical correlation.

publication date

  • April 2008