Abstract

Disk type windings are widely used in large power transformers. Block washers are used within some designs of this winding type to help to direct the oil flow. These washers increase the heat transfer coefficient, decrease hot spot temperature and consequently make the transformer smaller.A proper model is helpful to calculate the temperature distribution inside a natural convective cooled disk type winding including block washers. Therefore, in this paper a mathematical thermal model is presented and its validity and accuracy is verified with experimental measured data. Meanwhile, the effects of some parameters such as heat loss, number of washers, height of radiators and channel geometry are investigated using the model.

Authors

Rahimpour E; Barati M; Schäfer M

Journal

Applied Thermal Engineering, Vol. 27, No. 11-12, pp. 1923–1930

Publisher

Elsevier

Publication Date

August 1, 2007

DOI

10.1016/j.applthermaleng.2006.12.019

ISSN

1359-4311