Home
Scholarly Works
Oxygen-17 contrast agents. Fast imaging...
Journal article

Oxygen-17 contrast agents. Fast imaging techniques.

Abstract

Under physiologic conditions the stable isotope oxygen-17, in the form of O-17 water, lowers the proton T2 of blood, CSF, tissues, and whole organisms. With MRI the resulting changes in intensity can be detected using spin-echo pulse sequences, but much greater sensitivity is achieved in a fraction of the time with a steady-state free precession sequence such as FISP. With this sequence it is possible to detect levels as low as 0.4% Oxygen-17 water in 53 seconds or less.

Authors

Hopkins AL; Haacke EM; Barr RG; Tkach J

Journal

Invest Radiol, Vol. 23 Suppl 1, , pp. S240–S242

Publication Date

September 1, 1988

DOI

10.1097/00004424-198809001-00050

ISSN

0020-9996