Abstract

A fast neutron spectrometer based on an NE 213 liquid scintillator cell has been developed. For good spatial resolution within a water phantom, the cylindrical scintillator is small (1.5 cm diameter*1.5 cm length). Discrimination between neutron and gamma-ray induced ionisation events in the scintillator is effected on the basis of scintillation pulse shape. Some preliminary measurements of the fast neutron spectrum of a 10 Ci 238Pu-Be isotopic neutron source are presented.

Authors

Mountford PJ; Chettle DR; Fremlin JH; Thomas BJ

Journal

Physics in Medicine and Biology, Vol. 24, No. 3, pp. 647–650

Publisher

IOP Publishing

Publication Date

May 1, 1979

DOI

10.1088/0031-9155/24/3/018

ISSN

0031-9155